找出戴尔控制器退化的原因

我在几台PE 2950上安装了开放式pipe理,用于snmp监控RAID。 除了controllerState之外,所有的检查似乎都恢复正常:

  [root @ aMachine〜]#snmpwalk -v 2c -c bestNotToPostPasswords myMachine -m + StorageManagement-MIB controllerstate
     StorageManagement-MIB :: controllerState.1 = INTEGER:降级(6)

其他检查似乎表明电池,LD和物理磁盘都很好,除非我错过了一些东西。 任何人都可以告诉我是否缺less某些东西,或者忽略在我的RAID监控/理解中导入的东西? 我已经设置了这两个服务器降级。

整个存储pipe理树的散步:

 StorageManagement-MIB :: softwareVersion.0 = STRING:“3.2.0”
 StorageManagement-MIB :: globalStatus.0 = INTEGER:warning(2)
 StorageManagement-MIB :: softwareManufacturer.0 = STRING:“Dell Inc.”
 StorageManagement-MIB :: softwareProduct.0 = STRING:“Server Administrator(存储pipe理)”
 StorageManagement-MIB :: softwareDescription.0 = STRING:“configuration和监控磁盘存储设备”。
 StorageManagement-MIB :: displayName.0 = STRING:“Server Administrator(存储pipe理)”
 StorageManagement-MIB :: description.0 = STRING:“configuration和监控磁盘存储设备”。
 StorageManagement-MIB :: agentVendor.0 = STRING:“Dell Inc.”
 StorageManagement-MIB :: agentTimeStamp.0 = INTEGER:1273842310
 StorageManagement-MIB :: agentGetTimeout.0 = INTEGER:5
 StorageManagement-MIB :: agentModifiers.0 = INTEGER:0
 StorageManagement-MIB :: agentRefreshRate.0 = INTEGER:300
 StorageManagement-MIB :: agentMibVersion.0 = STRING:“3.2”
 StorageManagement-MIB :: agentManagementSoftwareURLName.0 =“”
 StorageManagement-MIB :: agentGlobalSystemStatus.0 = INTEGER:nonCritical(4)
 StorageManagement-MIB :: agentLastGlobalSystemStatus.0 = INTEGER:ok(3)
 StorageManagement-MIB :: agentSmartThermalShutdown.0 = INTEGER:notApplicable(3)
 StorageManagement-MIB :: controllerNumber.1 = INTEGER:1
 StorageManagement-MIB :: controllerName.1 = STRING:“PERC 5 / i集成”
 StorageManagement-MIB :: controllerVendor.1 = STRING:“DELL”
 StorageManagement-MIB :: controllerType.1 = INTEGER:sas(6)
 StorageManagement-MIB :: controllerState.1 = INTEGER:降级(6)
 StorageManagement-MIB :: controllerRebuildRateInPercent.1 = INTEGER:30
 StorageManagement-MIB :: controllerFWVersion.1 = STRING:“5.0.2-0003”
 StorageManagement-MIB :: controllerCacheSizeInMB.1 = INTEGER:256
 StorageManagement-MIB :: controllerCacheSizeInBytes.1 = INTEGER:0
 StorageManagement-MIB :: controllerPhysicalDeviceCount.1 = INTEGER:5
 StorageManagement-MIB :: controllerLogicalDeviceCount.1 = INTEGER:1
 StorageManagement-MIB :: controllerRollUpStatus.1 = INTEGER:nonCritical(4)
 StorageManagement-MIB :: controllerComponentStatus.1 = INTEGER:nonCritical(4)
 StorageManagement-MIB :: controllerNexusID.1 = STRING:“\\ 0”
 StorageManagement-MIB :: controllerAlarmState.1 = INTEGER:disabled(2)
 StorageManagement-MIB :: controllerDriverVersion.1 = STRING:“00.00.03.05
 “
 StorageManagement-MIB :: controllerPCISlot.1 = STRING:“embedded”
 StorageManagement-MIB :: controllerClusterMode.1 = INTEGER:notApplicable(99)
 StorageManagement-MIB :: controllerMinFWVersion.1 = STRING:“5.2.1-0067”
 StorageManagement-MIB :: controllerMinDriverVersion.1 = STRING:“00.00.03.21”
 StorageManagement-MIB :: controllerChannelCount.1 = INTEGER:2
 StorageManagement-MIB :: controllerReconstructRate.1 = INTEGER:30
 StorageManagement-MIB :: controllerPatrolReadRate.1 = INTEGER:30
 StorageManagement-MIB :: controllerBGIRate.1 = INTEGER:30
 StorageManagement-MIB :: controllerCheckConsistencyRate.1 = INTEGER:30
 StorageManagement-MIB :: controllerPatrolReadMode.1 = INTEGER:automatic(1)
 StorageManagement-MIB :: controllerPatrolReadState.1 = INTEGER:停止(1)
 StorageManagement-MIB :: controllerPatrolReadIterations.1 = INTEGER:162
 StorageManagement-MIB :: controllerEntry.57.1​​ = INTEGER:99
 StorageManagement-MIB :: controllerEntry.58.1 = INTEGER:99
 StorageManagement-MIB :: channelNumber.1 = INTEGER:1
 StorageManagement-MIB :: channelNumber.2 = INTEGER:2
 StorageManagement-MIB :: channelName.1 = STRING:“连接器0”
 StorageManagement-MIB :: channelName.2 = STRING:“连接器1”
 StorageManagement-MIB :: channelState.1 = INTEGER:ready(1)
 StorageManagement-MIB :: channelState.2 = INTEGER:ready(1)
 StorageManagement-MIB :: channelRollUpStatus.1 = INTEGER:ok(3)
 StorageManagement-MIB :: channelRollUpStatus.2 = INTEGER:ok(3)
 StorageManagement-MIB :: channelComponentStatus.1 = INTEGER:ok(3)
 StorageManagement-MIB :: channelComponentStatus.2 = INTEGER:ok(3)
 StorageManagement-MIB :: channelNexusID.1 = STRING:“\\ 0 \\ 0”
 StorageManagement-MIB :: channelNexusID.2 = STRING:“\\ 0 \\ 1”
 StorageManagement-MIB :: channelBusType.1 = INTEGER:sas(8)
 StorageManagement-MIB :: channelBusType.2 = INTEGER:sas(8)
 StorageManagement-MIB :: enclosureNumber.1 = INTEGER:1
 StorageManagement-MIB :: enclosureName.1 = STRING:“Backplane”
 StorageManagement-MIB :: enclosureVendor.1 = STRING:“DELL”
 StorageManagement-MIB :: enclosureState.1 = INTEGER:ready(1)
 StorageManagement-MIB :: enclosureProductID.1 = STRING:“BACKPLANE”
 StorageManagement-MIB :: enclosureType.1 = INTEGER:internal(1)
 StorageManagement-MIB :: enclosureChannelNumber.1 = INTEGER:0
 StorageManagement-MIB :: enclosureRollUpStatus.1 = INTEGER:ok(3)
 StorageManagement-MIB :: enclosureComponentStatus.1 = INTEGER:ok(3)
 StorageManagement-MIB :: enclosureNexusID.1 = STRING:“\\ 0 \\ 0 \\ 0”
 StorageManagement-MIB :: enclosureFirmwareVersion.1 = STRING:“1.00”
 StorageManagement-MIB :: enclosureSASAddress.1 = STRING:“50019090B4C67200”
 StorageManagement-MIB :: arrayDiskNumber.1 = INTEGER:1
 StorageManagement-MIB :: arrayDiskNumber.2 = INTEGER:2
 StorageManagement-MIB :: arrayDiskNumber.3 = INTEGER:3
 StorageManagement-MIB :: arrayDiskNumber.4 = INTEGER:4
 StorageManagement-MIB :: arrayDiskName.1 = STRING:“Physical Disk 0:0:0”
 StorageManagement-MIB :: arrayDiskName.2 = STRING:“物理磁盘0:0:1”
 StorageManagement-MIB :: arrayDiskName.3 = STRING:“物理磁盘0:0:2”
 StorageManagement-MIB :: arrayDiskName.4 = STRING:“物理磁盘0:0:3”
 StorageManagement-MIB :: arrayDiskVendor.1 = STRING:“DELL”
 StorageManagement-MIB :: arrayDiskVendor.2 = STRING:“DELL”
 StorageManagement-MIB :: arrayDiskVendor.3 = STRING:“DELL”
StorageManagement-MIB::arrayDiskVendor.4 = STRING: "DELL "
StorageManagement-MIB::arrayDiskState.1 = INTEGER: online(3)
StorageManagement-MIB::arrayDiskState.2 = INTEGER: online(3)
StorageManagement-MIB::arrayDiskState.3 = INTEGER: online(3)
StorageManagement-MIB::arrayDiskState.4 = INTEGER: online(3)
StorageManagement-MIB::arrayDiskProductID.1 = STRING: "ST3146755SS "
StorageManagement-MIB::arrayDiskProductID.2 = STRING: "ST3146755SS "
StorageManagement-MIB::arrayDiskProductID.3 = STRING: "ST3146755SS "
StorageManagement-MIB::arrayDiskProductID.4 = STRING: "ST3146755SS "
StorageManagement-MIB::arrayDiskSerialNo.1 = STRING: "3LN0LRL0 "
StorageManagement-MIB::arrayDiskSerialNo.2 = STRING: "3LN0JYJS "
StorageManagement-MIB::arrayDiskSerialNo.3 = STRING: "3LN0LR0V "
StorageManagement-MIB::arrayDiskSerialNo.4 = STRING: "3LN0JH97 "
StorageManagement-MIB::arrayDiskRevision.1 = STRING: "T106"
StorageManagement-MIB::arrayDiskRevision.2 = STRING: "T106"
StorageManagement-MIB::arrayDiskRevision.3 = STRING: "T106"
StorageManagement-MIB::arrayDiskRevision.4 = STRING: "T106"
StorageManagement-MIB::arrayDiskEnclosureID.1 = STRING: "0"
StorageManagement-MIB::arrayDiskEnclosureID.2 = STRING: "0"
StorageManagement-MIB::arrayDiskEnclosureID.3 = STRING: "0"
StorageManagement-MIB::arrayDiskEnclosureID.4 = STRING: "0"
StorageManagement-MIB::arrayDiskChannel.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskChannel.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskChannel.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskChannel.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskLengthInMB.1 = INTEGER: 139392
StorageManagement-MIB::arrayDiskLengthInMB.2 = INTEGER: 139392
StorageManagement-MIB::arrayDiskLengthInMB.3 = INTEGER: 139392
StorageManagement-MIB::arrayDiskLengthInMB.4 = INTEGER: 139392
StorageManagement-MIB::arrayDiskLengthInBytes.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskLengthInBytes.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskLengthInBytes.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskLengthInBytes.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInMB.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskLargestContiguousFreeSpaceInBytes.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskTargetID.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskTargetID.2 = INTEGER: 1
StorageManagement-MIB::arrayDiskTargetID.3 = INTEGER: 2
StorageManagement-MIB::arrayDiskTargetID.4 = INTEGER: 3
StorageManagement-MIB::arrayDiskLunID.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskLunID.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskLunID.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskLunID.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskUsedSpaceInMB.1 = INTEGER: 139392
StorageManagement-MIB::arrayDiskUsedSpaceInMB.2 = INTEGER: 139392
StorageManagement-MIB::arrayDiskUsedSpaceInMB.3 = INTEGER: 139392
StorageManagement-MIB::arrayDiskUsedSpaceInMB.4 = INTEGER: 139392
StorageManagement-MIB::arrayDiskUsedSpaceInBytes.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskUsedSpaceInBytes.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskUsedSpaceInBytes.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskUsedSpaceInBytes.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInMB.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInMB.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInMB.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInMB.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInBytes.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInBytes.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInBytes.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskFreeSpaceInBytes.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskBusType.1 = INTEGER: sas(8)
StorageManagement-MIB::arrayDiskBusType.2 = INTEGER: sas(8)
StorageManagement-MIB::arrayDiskBusType.3 = INTEGER: sas(8)
StorageManagement-MIB::arrayDiskBusType.4 = INTEGER: sas(8)
StorageManagement-MIB::arrayDiskSpareState.1 = INTEGER: notASpare(5)
StorageManagement-MIB::arrayDiskSpareState.2 = INTEGER: notASpare(5)
StorageManagement-MIB::arrayDiskSpareState.3 = INTEGER: notASpare(5)
StorageManagement-MIB::arrayDiskSpareState.4 = INTEGER: notASpare(5)
StorageManagement-MIB::arrayDiskRollUpStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskRollUpStatus.2 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskRollUpStatus.3 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskRollUpStatus.4 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskComponentStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskComponentStatus.2 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskComponentStatus.3 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskComponentStatus.4 = INTEGER: ok(3)
StorageManagement-MIB::arrayDiskNexusID.1 = STRING: "\\0\\0\\0\\0"
StorageManagement-MIB::arrayDiskNexusID.2 = STRING: "\\0\\0\\0\\1"
StorageManagement-MIB::arrayDiskNexusID.3 = STRING: "\\0\\0\\0\\2"
StorageManagement-MIB::arrayDiskNexusID.4 = STRING: "\\0\\0\\0\\3"
StorageManagement-MIB::arrayDiskPartNumber.1 = STRING: "SG0DR2381253172FLRL0A00 "
StorageManagement-MIB::arrayDiskPartNumber.2 = STRING: "SG0DR2381253172FJYJSA00 "
StorageManagement-MIB::arrayDiskPartNumber.3 = STRING: "SG0DR2381253172FLR0VA00 "
StorageManagement-MIB::arrayDiskPartNumber.4 = STRING: "SG0DR2381253172FJH97A00 "
StorageManagement-MIB::arrayDiskSASAddress.1 = STRING: "5000C50002380201"
StorageManagement-MIB::arrayDiskSASAddress.2 = STRING: "5000C50002385B89"
StorageManagement-MIB::arrayDiskSASAddress.3 = STRING: "5000C50002385AA9"
StorageManagement-MIB::arrayDiskSASAddress.4 = STRING: "5000C500023841E1"
StorageManagement-MIB::arrayDiskSmartAlertIndication.1 = INTEGER: no(1)
StorageManagement-MIB::arrayDiskSmartAlertIndication.2 = INTEGER: no(1)
StorageManagement-MIB::arrayDiskSmartAlertIndication.3 = INTEGER: no(1)
StorageManagement-MIB::arrayDiskSmartAlertIndication.4 = INTEGER: no(1)
StorageManagement-MIB::arrayDiskManufactureDay.1 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureDay.2 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureDay.3 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureDay.4 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureWeek.1 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureWeek.2 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureWeek.3 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureWeek.4 = STRING: "07"
StorageManagement-MIB::arrayDiskManufactureYear.1 = STRING: "2005"
StorageManagement-MIB::arrayDiskManufactureYear.2 = STRING: "2005"
StorageManagement-MIB::arrayDiskManufactureYear.3 = STRING: "2005"
StorageManagement-MIB::arrayDiskManufactureYear.4 = STRING: "2005"
StorageManagement-MIB::arrayDiskMediaType.1 = INTEGER: hdd(2)
StorageManagement-MIB::arrayDiskMediaType.2 = INTEGER: hdd(2)
StorageManagement-MIB::arrayDiskMediaType.3 = INTEGER: hdd(2)
StorageManagement-MIB::arrayDiskMediaType.4 = INTEGER: hdd(2)
StorageManagement-MIB::arrayDiskEntry.36.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskEntry.36.2 = INTEGER: 1
StorageManagement-MIB::arrayDiskEntry.36.3 = INTEGER: 1
StorageManagement-MIB::arrayDiskEntry.36.4 = INTEGER: 1
StorageManagement-MIB::arrayDiskEntry.40.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.40.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.40.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.40.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.41.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.41.2 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.41.3 = INTEGER: 0
StorageManagement-MIB::arrayDiskEntry.41.4 = INTEGER: 0
StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.2 = INTEGER: 2
StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.3 = INTEGER: 3
StorageManagement-MIB::arrayDiskEnclosureConnectionNumber.4 = INTEGER: 4
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0"
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1"
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2"
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3"
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.2 = INTEGER: 2
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.3 = INTEGER: 3
StorageManagement-MIB::arrayDiskEnclosureConnectionArrayDiskNumber.4 = INTEGER: 4
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.1 = STRING: "Backplane"
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.2 = STRING: "Backplane"
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.3 = STRING: "Backplane"
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureName.4 = STRING: "Backplane"
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.2 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.3 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionEnclosureNumber.4 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.1 = STRING: "PERC 5/i Integrated"
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.2 = STRING: "PERC 5/i Integrated"
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.3 = STRING: "PERC 5/i Integrated"
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerName.4 = STRING: "PERC 5/i Integrated"
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.2 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.3 = INTEGER: 1
StorageManagement-MIB::arrayDiskEnclosureConnectionControllerNumber.4 = INTEGER: 1
StorageManagement-MIB::batteryNumber.1 = INTEGER: 1
StorageManagement-MIB::batteryName.1 = STRING: "Battery 0"
StorageManagement-MIB::batteryVendor.1 = STRING: "DELL"
StorageManagement-MIB::batteryState.1 = INTEGER: ready(1)
StorageManagement-MIB::batteryRollUpStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::batteryComponentStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::batteryNexusID.1 = STRING: "\\0\\0"
StorageManagement-MIB::batteryPredictedCapacity.1 = INTEGER: ready(2)
StorageManagement-MIB::batteryNextLearnTime.1 = INTEGER: 21
StorageManagement-MIB::batteryLearnState.1 = INTEGER: idle(16)
StorageManagement-MIB::batteryEntry.13.1 = INTEGER: 0
StorageManagement-MIB::batteryMaxLearnDelay.1 = INTEGER: 168
StorageManagement-MIB::batteryConnectionNumber.1 = INTEGER: 1
StorageManagement-MIB::batteryConnectionBatteryName.1 = STRING: "Battery 0"
StorageManagement-MIB::batteryConnectionBatteryNumber.1 = INTEGER: 1
StorageManagement-MIB::batteryConnectionControllerName.1 = STRING: "PERC 5/i Integrated"
StorageManagement-MIB::batteryConnectionControllerNumber.1 = INTEGER: 1
StorageManagement-MIB::virtualDiskNumber.1 = INTEGER: 1
StorageManagement-MIB::virtualDiskName.1 = STRING: "Virtual Disk 0"
StorageManagement-MIB::virtualDiskDeviceName.1 = STRING: "/dev/sda"
StorageManagement-MIB::virtualDiskState.1 = INTEGER: ready(1)
StorageManagement-MIB::virtualDiskLengthInMB.1 = INTEGER: 278784
StorageManagement-MIB::virtualDiskLengthInBytes.1 = INTEGER: 0
StorageManagement-MIB::virtualDiskWritePolicy.1 = INTEGER: writeBack(3)
StorageManagement-MIB::virtualDiskReadPolicy.1 = INTEGER: noReadAhead(5)
StorageManagement-MIB::virtualDiskCachePolicy.1 = INTEGER: not-applicable(99)
StorageManagement-MIB::virtualDiskLayout.1 = INTEGER: raid-10(10)
StorageManagement-MIB::virtualDiskCurStripeSizeInMB.1 = INTEGER: 0
StorageManagement-MIB::virtualDiskCurStripeSizeInBytes.1 = INTEGER: 65536
StorageManagement-MIB::virtualDiskTargetID.1 = INTEGER: 0
StorageManagement-MIB::virtualDiskRollUpStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::virtualDiskComponentStatus.1 = INTEGER: ok(3)
StorageManagement-MIB::virtualDiskNexusID.1 = STRING: "\\0\\0"
StorageManagement-MIB::virtualDiskArrayDiskType.1 = INTEGER: sas(1)
StorageManagement-MIB::virtualDiskEntry.23.1 = INTEGER: 2
StorageManagement-MIB::virtualDiskEntry.24.1 = INTEGER: 0
StorageManagement-MIB::arrayDiskLogicalConnectionNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskLogicalConnectionNumber.2 = INTEGER: 2
StorageManagement-MIB::arrayDiskLogicalConnectionNumber.3 = INTEGER: 3
StorageManagement-MIB::arrayDiskLogicalConnectionNumber.4 = INTEGER: 4
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.1 = STRING: "Physical Disk 0:0:0"
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.2 = STRING: "Physical Disk 0:0:1"
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.3 = STRING: "Physical Disk 0:0:2"
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskName.4 = STRING: "Physical Disk 0:0:3"
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.2 = INTEGER: 2
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.3 = INTEGER: 3
StorageManagement-MIB::arrayDiskLogicalConnectionArrayDiskNumber.4 = INTEGER: 4
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.1 = STRING: "Virtual Disk 0"
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.2 = STRING: "Virtual Disk 0"
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.3 = STRING: "Virtual Disk 0"
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskName.4 = STRING: "Virtual Disk 0"
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.1 = INTEGER: 1
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.2 = INTEGER: 1
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.3 = INTEGER: 1
StorageManagement-MIB::arrayDiskLogicalConnectionVirtualDiskNumber.4 = INTEGER: 1

Update in Response To Battery Question:
Not entirely sure about the age, a few years? Maybe this helps:

[root@aMachine ~]# /opt/MegaRAID/MegaCli/MegaCli -AdpBbuCmd -aALL

BBU status for Adapter: 0

BatteryType: BBU
Voltage: 4054 mV
Current: 0 mA
Temperature: 10 C
Firmware Status: 00000000

Battery state: 

GasGuageStatus:
  Fully Discharged : No
  Fully Charged : Yes
  Discharging : Yes
  Initialized : Yes
  Remaining Time Alarm : No
  Remaining Capacity Alarm: No
  Discharge Terminated : No
  Over Temperature : No
  Charging Terminated : No
  Over Charged : No

Relative State of Charge: 100 %
Charger Status: Complete
Remaining Capacity: 1472 mAh
Full Charge Capacity: 1478 mAh
isSOHGood: Yes

BBU Capacity Info for Adapter: 0

Relative State of Charge: 100 %
Absolute State of charge: 77 %
Remaining Capacity: 1472 mAh
Full Charge Capacity: 1478 mAh
Run time to empty: 65535 Min
Average time to empty: 65535 Min
Average Time to full: 65535 Min
Cycle Count: 15
Max Error: 2 %
Remaining Capacity Alarm: 190 mAh
Remaining Time Alarm: 10 Min


BBU Design Info for Adapter: 0

Date of Manufacture: 01/09, 2007
Design Capacity: 1900 mAh
Design Voltage: 3700 mV
Specification Info: 8000
Serial Number: 2991
Pack Stat Configuration: 0xe49c
Manufacture Name: SMP-PA
Device Name: X848371
Device Chemistry: LION


BBU Properties for Adapter: 0

Auto Learn Period: 7776000 Sec
Next Learn time: 327149518 Sec 
Learn Delay Interval:0 Hours
Auto-Learn Mode: Enabled

Update 2, this is just to go for a question length record:
Hmm.. One of the two it turns out that the battery is about to start this process on its own. However, this doesn't seem to be the case on the other one. So I am thinking it is something else?

function gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'zh-CN', function () {});} / opt / MegaRAID / MegaCli / MegaCli -FwTermLog -Dsply -aALL ... 05/08/10 3:40:18:下一个PR预定开始于05/15/10 3:00:00 05/10/10 10 :52:14:EVT#08474-05 / 10/10 10:52:14:157 =电池再学习将在4天内开始05/12/10 10:52:49:EVT#08475-05 / 12/10 10 :52:49:158 =电池再学习将在2天开始05/13/10 10:52:34:EVT#08476-05 / 13/10 10:52:34:159 =电池再学习将在1天开始05 / 13/10 15:43:08:EVT#08477-05 / 13/10 15:43:08:73 = VD 00/0属性更新为[ID = 00,dcp = 01,ccp = 01,ap = 0 (从ID = 00,dcp = 01,ccp = 01,ap = 0,dc = 0,dbgi = 0))05/13/10 13:30:22:EVT# 08478-05 / 13/10 13:30:22:44 =时间确定为05/13/10 13:30:22;  (5228737秒开机)05/13/10 13:30:24:EVT#08479-05 / 13/10 13:30:24:30 =事件日志清零05/13/10 13:30:54:EVT #08480-05 / 13/10 13:30:54:30 =清除事件日志05/13/10 13:31:12:EVT#08481-05 / 13/10 13:31:12:30 =清除事件日志05/13/10 13:31:31:EVT#08482-05 / 13/10 13:31:31:30 =事件日志清零05/14/10 5:52:43:EVT#08483-05 / 14 / 10 5:52:43:160 =电池重新学习将在5个小时内开始 

控制器状态要求控制器固件和内核模块(驱动程序)都是最新的。 一旦我更新了这两个控制器状态更改为“就绪”。

你的服务器多大? 在戴尔文档中,控制器的退化状态意味着电池应该被修复。 通常这是自动完成的,但如果太旧,则需要更改。

PS:如果您安装了openmanage,则可以select手动修复电池。 小心,因为这项任务需要约8-10小时,在这段时间电池放电和充电。

正如我一直告诉人们的 – 为什么依靠在线支持,何时可以打电话给供应商支持? 戴尔这样的问题在现场解决,只需要很less的工作。

话虽如此,我要做的就是重新安装BBU,如果可能的话,将其与另外一台PE9250进行交换。 如果这没有帮助,你可能需要更换。