3com交换机已经设置为转发状态

我在3com交换机系统日志上收到此错误。

Oct 4 10:25:25:367 2013 MSTP Information MSTP_FORWARDING Instance 0's port GigabitEthernet1/0/37 has been set to forwarding state. Oct 4 10:25:25:352 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/37 link status is UP. Oct 4 10:25:19:545 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/37 link status is DOWN. Oct 4 10:15:52:389 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/23 link status is DOWN. Oct 4 10:15:46:377 2013 MSTP Information MSTP_FORWARDING Instance 0's port GigabitEthernet1/0/35 has been set to forwarding state. Oct 4 10:15:46:362 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/35 link status is UP. Oct 4 10:15:14:251 2013 MSTP Information MSTP_FORWARDING Instance 0's port GigabitEthernet1/0/23 has been set to forwarding state. Oct 4 10:15:14:236 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/23 link status is UP. Oct 4 10:15:12:433 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/23 link status is DOWN. Oct 4 10:06:28:139 2013 IFNET Error LINK_UPDOWN GigabitEthernet1/0/35 link status is DOWN. Oct 4 10:06:11:916 2013 MSTP Information MSTP_FORWARDING Instance 0's port GigabitEthernet1/0/4 has been set to forwarding state. 

我应该离开还是configuration一些东西?

哪一部分你不确定?

MSTP消息只是说明端口已进入MSTP转发状态。 发生这种情况是因为端口已经上电(即电缆连接)

我不确定3com为什么会将端口logging为错误信息,但是它告诉你一个电缆被(un)插入(oe交换机端口在链路的一端被pipe理性地启用/禁用)。 你期望这些消息? (也就是说,当时是否有人插入/拔出电缆?)。 如果没有,那么你很可能有一个需要识别和固定的电缆问题(连接器松动,接线错误等)。