惠普acu驱动器列表错误。 智能arrays

我有当前configurationHP Proliant BL460gen6与控制器智能arraysP711M Ubuntu操作系统有35个硬盘configuration在RAID 1 + 0与1磁盘备用通常我监视RAID的默认命令的状态

hpacucli ctrl所有显示configuration

如果发现失败的磁盘,我将其replace。 偶然,我注意到二极pipe是存储系统上的两个硬盘坏掉的信号。 同时,报告中的hpacucli表示,所有硬盘都是正常的。 谷歌search后,我得到了另一个版本的hpacucli语法

hpacucli ctrl slot = 2 ld 1 show

实施后,确认存在有问题的硬盘驱动器。更换一个硬盘驱动器继续监测情况,恢复的RAID发生在正常模式,但是,列表中的硬盘驱动器的编号是错误的双倍驱动器号码

更换的HDD位于插槽2中

hpacucli ctrl所有显示configuration

Smart Array P711m in Slot 2 array A (SATA, Unused Space: 0 MB) logicaldrive 1 (61.9 TB, RAID 1+0, Recovering, 75% complete) physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK) physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK) physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding) physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding) physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK) physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK) physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK) physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK) physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK) physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK) physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK) physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK) physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK) physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK) physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK) physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK) physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK) physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK) physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK) physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK) physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK) physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK) physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK) physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK) physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK) physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK) physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK) physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK) physicaldrive 1E:1:15 (port 1E:box 1:bay 15, SATA, 4000.7 GB, OK) physicaldrive 1E:1:16 (port 1E:box 1:bay 16, SATA, 4000.7 GB, OK) physicaldrive 1E:1:17 (port 1E:box 1:bay 17, SATA, 4000.7 GB, OK) physicaldrive 1E:1:18 (port 1E:box 1:bay 18, SATA, 4000.7 GB, OK) physicaldrive 1E:1:19 (port 1E:box 1:bay 19, SATA, 4000.7 GB, OK) physicaldrive 1E:1:20 (port 1E:box 1:bay 20, SATA, 4000.7 GB, OK) physicaldrive 1E:1:21 (port 1E:box 1:bay 21, SATA, 4000.7 GB, OK, active spare) 

hpacucli ctrl slot = 2 ld 1 show

  Smart Array P711m in Slot 2 array A Logical Drive: 1 Size: 61.9 TB Fault Tolerance: 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 256 KB Full Stripe Size: 4352 KB Status: Recovering, 78% complete MultiDomain Status: OK Caching: Enabled Unique Identifier: Disk Name: /dev/sda Mount Points: None Logical Drive Label: Mirror Group 0: physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK) physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Rebuilding) physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK) physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 4000.7 GB, OK) physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 4000.7 GB, OK) physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 4000.7 GB, OK) physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 4000.7 GB, OK) physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 4000.7 GB, OK) physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 4000.7 GB, OK) physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 4000.7 GB, OK) physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 4000.7 GB, OK) physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 4000.7 GB, OK) physicaldrive 1E:1:13 (port 1E:box 1:bay 13, SATA, 4000.7 GB, OK) physicaldrive 1E:1:14 (port 1E:box 1:bay 14, SATA, 4000.7 GB, OK) physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 4000.7 GB, OK) physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 4000.7 GB, Failed) physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 4000.7 GB, OK) 

什么错了,我怎么能修复它,为什么不同的hpacucli命令返回不同的硬盘状态

您可能有双域电缆(多pathSAS)。

P711是刀片服务器SAS RAID控制器,用于连接刀片服务器机箱扩展端口(SAS交换机)并连接到更大的机箱(如D6000 35或70托架SAS JBOD)。

在这里输入图像说明

在这里输入图像说明

这可能是你所拥有的。 等待磁盘重build。

另外,您不应该像监视RAID一样监视RAID状态。 您只需安装HPpipe理代理,系统将通过电子邮件或发送SNMP陷阱来更改健康状况。

请参阅: 监控HP ProLiant DL380 G7

使用hplog -v也会显示所有的系统警报。