HP DL180 G6:温度传感器#21

随着炎热的夏季日子的开始,我的服务器越来越多地进入热保护closures,由于温度传感器#21达到临界水平(58 * C),如国际劳工组织报告。

风扇都运行良好,但不幸的是,服务器不在气候控制室,我可以做的环境温度不是很多。 但是,如果我知道传感器#21在哪里,我可以尝试改善该区域周围的气stream。 如果是IC,我可以增加/加强散热器来改善散热。

有人知道传感器在哪里吗?

编辑:

夜间等级:

Location Status Reading Thresholds Temp 1: System Zone Ok 15C Caution: 42C; Critical:47C Temp 2 (CPU 1): System 1 Ok 40C Caution: 82C; Critical:83C Temp 3 (CPU 2): System 2 Ok 40C Caution: 82C; Critical:83C Temp 4: Memory Zone Ok 37C Caution: 87C; Critical:92C Temp 5: Memory Zone Ok 41C Caution: 87C; Critical:92C Temp 6: System Zone n/an/a Caution: 99C; Critical:99C Temp 7: System Zone n/an/a Caution: 99C; Critical:99C Temp 8 (MemB0): Memory Zone Ok 34C Caution: 62C; Critical:67C Temp 9 (MemB0): Memory Zone Ok 34C Caution: 61C; Critical:66C Temp 10 (MemB0): Memory Zone Ok 33C Caution: 61C; Critical:66C Temp 12 (MemB1): Memory Zone Ok 38C Caution: 66C; Critical:71C Temp 13 (MemB1): Memory Zone Ok 39C Caution: 65C; Critical:70C Temp 14 (MemB1): Memory Zone Ok 38C Caution: 70C; Critical:75C Temp 15: System Zone Ok 40C Caution: 57C; Critical:62C Temp 16: System Zone Ok 33C Caution: 50C; Critical:55C Temp 17: System Zone Ok 35C Caution: 58C; Critical:63C Temp 18: System Zone Ok 45C Caution: 110C; Critical:115C Temp 19: System Zone Ok 41C Caution: 57C; Critical:62C Temp 20: System Zone Ok 42C Caution: 53C; Critical:58C Temp 21: System Zone Ok 49C Caution: 53C; Critical:58C Temp 22 (PCIR): I/O Board Zone n/an/a Caution: 99C; Critical:99C Temp 23 (PCIR): I/O Board Zone n/an/a Caution: 99C; Critical:99C Temp 24 (PCIR): I/O Board Zone n/an/a Caution: 99C; Critical:99C Temp 25 (PCIR): I/O Board Zone n/an/a Caution: 99C; Critical:99C Temp 26: Storage Zone Ok 0C Caution: 99C; Critical:99C Temp 27: Storage Zone Ok 0C Caution: 99C; Critical:99C Temp 28: Storage Zone Ok 0C Caution: 99C; Critical:99C Temp 29: Storage Zone Ok 0C Caution: 99C; Critical:99C Temp 30: Storage Zone Ok 0C Caution: 99C; Critical:99C Temp 31: Storage Zone Ok 0C Caution: 99C; Critical:99C 

提前谢谢了。

21号传感器是否重要? 你会怎么呢?

你能检查你的环境温度吗? 你可以控制你的环境,以保持在合理的范围内? 你确定你没有失败的粉丝吗?

– 编辑 –

确保所有组件的固件是最新的是有意义的。 对于你来说,这意味着你的系统BIOS,ILO,RAID控制器,网卡,背板和磁盘。 这些都可以由惠普支持惠普支持包的ProLiant启动DVD 。 请下载并运行。

检查服务器上的内部健康LED。 如果您运行的是受支持的Linux或Windows版本,请安装HPpipe理代理并检查hplog -t的输出以获取温度传感器信息。 标准DL180 G6configuration的输出如下所示。 关联您的结果与我的:

注意:这个系统中有四个风扇

 # hplog -f ID TYPE LOCATION STATUS REDUNDANT FAN SPEED 1 Var. Speed System Board Normal N/A Normal ( 55) 2 Var. Speed System Board Normal N/A Normal ( 59) 3 Var. Speed System Board Normal N/A Normal ( 63) 4 Var. Speed System Board Normal N/A Normal ( 53) 

 # hplog -t ID TYPE LOCATION STATUS CURRENT THRESHOLD 1 Basic Sensor Mem. Brd. (1) Normal 78F/ 26C 188F/ 87C 2 Basic Sensor Mem. Brd. (1) Normal 78F/ 26C 188F/ 87C 3 Basic Sensor Mem. Brd. (1) Normal 82F/ 28C 188F/ 87C 4 Basic Sensor Mem. Brd. (1) Absent ---F/---C ---F/---C 5 Basic Sensor Mem. Brd. (1) Normal 80F/ 27C 188F/ 87C 6 Basic Sensor Mem. Brd. (1) Absent ---F/---C ---F/---C 7 Basic Sensor Mem. Brd. (1) Normal 104F/ 40C 203F/ 95C 8 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 9 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 10 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 11 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 12 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 13 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 14 Basic Sensor Mem. Brd. (2) Absent ---F/---C ---F/---C 15 Basic Sensor System Board Absent ---F/---C ---F/---C 16 Basic Sensor System Board Absent ---F/---C ---F/---C 17 Basic Sensor Ambient Normal 71F/ 22C 140F/ 60C 18 Basic Sensor Ambient Normal 80F/ 27C 158F/ 70C 19 Basic Sensor System Board Normal 68F/ 20C 233F/112C 20 Basic Sensor System Board Normal 86F/ 30C 174F/ 79C 21 Basic Sensor System Board Normal 73F/ 23C 140F/ 60C 22 Basic Sensor System Board Normal 75F/ 24C 143F/ 62C 23 Basic Sensor System Board Normal 75F/ 24C 143F/ 62C 24 Basic Sensor System Board Normal 71F/ 22C 143F/ 62C 25 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C 26 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C 27 Basic Sensor System Board Normal 71F/ 22C 172F/ 78C 28 Basic Sensor System Board Normal 77F/ 25C 185F/ 85C 29 Basic Sensor System Board Normal 75F/ 24C 185F/ 85C 30 Basic Sensor System Board Normal 77F/ 25C 185F/ 85C 31 Basic Sensor System Board Normal 84F/ 29C 159F/ 71C 32 Basic Sensor System Board Normal 86F/ 30C 176F/ 80C 33 Basic Sensor System Board Normal 68F/ 20C 140F/ 60C 34 Basic Sensor System Board Normal 68F/ 20C 140F/ 60C 35 Basic Sensor System Board Normal 107F/ 42C 230F/110C