我正在使用基于RAID50的12 x 3TB硬盘的带有BBU的HP P410 raid卡
数据中心停电后,Hpacucli显示:
奇偶校验初始化状态:初始化失败
但是,所有的磁盘似乎是可操作的:
Parity Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 3 TB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 3 TB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 3 TB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 3 TB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SATA, 3 TB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SATA, 3 TB, OK) Parity Group 1: physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SATA, 3 TB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SATA, 3 TB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SATA, 3 TB, OK) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SATA, 3 TB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SATA, 3 TB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SATA, 3 TB, OK)
在ADU报告中我找不到任何关于错误的信息。
服务器正在生产中,我很害怕丢失数据,因为奇偶校验不在线。 我能做些什么来重新初始化奇偶校验初始化?
如果我做hpacucli ctrl插槽= 0 ld 2修改raid = 50 ,我会失去数据或将它只是重新启动初始化?
这里是完整的hpacucli输出: http ://pastebin.com/raw.php?i=19YJ6aWF
这是ADU报告: https : //www.dropbox.com/s/dyptmea8z3qwlsq/ADU%20Report%20Viewer.html
这需要时间。
从控制器技术指南 :
创buildRAID 1,RAID 5或RAID 6逻辑驱动器时,智能arrays控制器必须在arrays中构build逻辑驱动器,并在启用某些高级性能技术之前初始化奇偶校验。 奇偶校验初始化需要几个小时才能完成。 所花费的时间取决于逻辑驱动器的大小和控制器上的负载。 智能arrays控制器创build逻辑驱动器,每当控制器不忙时,初始化奇偶校验。
另请参阅: HP ACU显示智能arrays控制器上的奇偶校验初始化失败