是否可以缩小HP Smart Array逻辑驱动器的大小?

我知道扩展是很有可能使用hpacucli实用程序,但有没有简单的方法来减less现有的逻辑驱动器(而不是数组)的大小?

控制器是ProLiant DL360 G6服务器中的P410i。 我想将逻辑驱动器1从72GB减less到40GB。

 => ctrl all show config detail Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Slot: 0 Serial Number: 5001438006FD9A50 Cache Serial Number: PAAVP9VYFB8Y RAID 6 (ADG) Status: Disabled Controller Status: OK Chassis Slot: Hardware Revision: Rev C Firmware Version: 3.66 Rebuild Priority: Medium Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Accelerator Ratio: 25% Read / 75% Write Drive Write Cache: Enabled Total Cache Size: 512 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Batteries Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SAS Unused Space: 412476 MB Status: OK Logical Drive: 1 Size: 72.0 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 18504 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: 600508B1001C132E4BBDFAA6DAD13DA3 Disk Name: /dev/cciss/c0d0 Mount Points: /boot 196 MB, / 12.0 GB, /usr 8.0 GB, /var 4.0 GB, /tmp 2.0 GB OS Status: LOCKED Logical Drive Label: AE438D6A5001438006FD9A50BE0A Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 146 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 146 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 Device Number: 250 Firmware Version: RevC WWID: 5001438006FD9A5F Vendor ID: PMCSIERA Model: SRC 8x6G 

SAconfiguration指南的第41页说不。 您只能创build,删除,扩展和迁移(以及一些信息和恢复命令)。

你可以尝试从Parted Magic启动,看看你是否可以resize? 我发现它非常有帮助。

如果不是引导驱动器,则备份数据并创build一个新的分区。