我一直有一些间歇性故障的问题,并在我们的带有P410控制器的HP DL160 G6上重build消息。
作为故障排除的一部分,我更换了SATA电缆,并在启动时,现在控制器卡在临时恢复模式 。 它认为一个驱动器已经失败,但仍然连接(?),并有一个未分配的驱动器,它没有开始重build。
=> ctrl all show config Smart Array P410 in Slot 0 (Embedded) (sn: ) Port Name: 1I Port Name: 2I array A (SATA, Unused Space: 0 MB) logicaldrive 1 (50.0 GB, RAID 5, Interim Recovery Mode) logicaldrive 2 (10.9 TB, RAID 5, Interim Recovery Mode) physicaldrive 1I:0:3 (port 1I:box 0:bay 3, SATA, 0 MB, Failed) physicaldrive 2I:0:5 (port 2I:box 0:bay 5, SATA, 4000.7 GB, OK) physicaldrive 2I:0:6 (port 2I:box 0:bay 6, SATA, 4000.7 GB, OK) physicaldrive 2I:0:8 (port 2I:box 0:bay 8, SATA, 4000.7 GB, OK) unassigned physicaldrive 2I:0:7 (port 2I:box 0:bay 7, SATA, 4000.7 GB, OK)
我已经尝试过ctrl slot=0 array A remove drives=1I:0:3删除失败的一个,和ctrl slot=0 array A add drives=2I:0:7添加未分配的开始重build。
这两个命令失败,出现以下错误:
Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. Reason: Array is transforming
这是一个4x4TB驱动器的RAID 5arrays。
有什么build议吗?
您需要确保将驱动器连接到背板上的同一端口,或者重新调整电缆的方向以使驱动器进入位置1.否则,将不会检测到该驱动器。
编辑:
它看起来像你的磁盘是在错误的端口或连接到错误的电缆。