在我的HP Proliant服务器上,我有热添加了2个额外的驱动器。 为了扩大当前RAID 1arrays,我使用了以下命令:
hpacucli ctrl slot=0 logicaldrive 1 modify raid=1+0 hpacucli ctrl slot=0 ld 1 add drives=allunassigned
现在逻辑驱动器看起来像这样:
# hpacucli ctrl slot=0 logicaldrive 1 show Smart Array P410i in Slot 0 (Embedded) array A Logical Drive: 1 Size: 136.7 GB Fault Tolerance: RAID 1+0 Heads: 255 Sectors Per Track: 32 Cylinders: 35132 Strip Size: 256 KB Status: OK Array Accelerator: Enabled Unique Identifier: ************************** Disk Name: /dev/sda Mount Points: /boot 511 MB Logical Drive Label: ************************** Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
现在尺寸是这个136.7 GB,所以我尝试了下面的命令,但得到了一个警告:
# hpacucli ctrl slot=0 logicaldrive 1 modify size=max Warning: Extension may not be supported on certain operating systems. Performing extension on these operating systems can cause data to become inaccessible. See ACU documentation for details. Continue? (y/n)
我想知道会发生什么,如果我说是的,如果它保存在一个正在运行的安装。
详细信息:内核为2.6.32-16-pve的64位debian squeeze(proxmox VE 2)。
你可以说是的。
但是,您的磁盘大小不一致。 您是否将300GB添加到146GB的镜像对中? 如果是这样,逻辑驱动器扩展后只能得到〜288GB的可用空间。
如果能够创造一个300GB的新型逻辑驱动器,并且能够充分利用这些驱动器的全部容量,您会更好吗?