在MSA50上报告重复的驱动器

我不知道为什么,但是每当我在MSA50的托架1或托架2中安装驱动器时,ACU都会报告托架中有两个驱动器:

托架外壳中的重复驱动器

这不会发生在任何其他海湾,但海湾1和2。

光盘盒连接到装有最新固件的SmartArray P812控制器,ACU也是最新版本。

在P812上使用不同的端口也无济于事。

我是否认为这不应该发生?

编辑:

这里来自ACU CLI的configuration细节:

=> ctrl all show config detail Smart Array P812 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: PAGXQ0ARHZG0UJ Cache Serial Number: PBCDF0CRHZF03D RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware Revision: C Firmware Version: 6.00-2 Rebuild Priority: High Expand Priority: Medium Surface Scan Delay: 3 secs Surface Scan Mode: Idle Queue Depth: Automatic Monitor and Performance Delay: 60 min Elevator Sort: Enabled Degraded Performance Optimization: Disabled Inconsistency Repair Policy: Disabled Wait for Cache Room: Disabled Surface Analysis Inconsistency Notification: Disabled Post Prompt Timeout: 15 secs Cache Board Present: True Cache Status: OK Cache Ratio: 75% Read / 25% Write Drive Write Cache: Disabled Total Cache Size: 1024 MB Total Cache Memory Available: 912 MB No-Battery Write Cache: Disabled Cache Backup Power Source: Capacitors Battery/Capacitor Count: 1 Battery/Capacitor Status: OK SATA NCQ Supported: True Array: A Interface Type: SATA Unused Space: 0 MB Status: OK MultiDomain Status: OK Array Type: Data Logical Drive: 1 Size: 5.5 TB Fault Tolerance: 5 Heads: 255 Sectors Per Track: 32 Cylinders: 65535 Strip Size: 512 KB Full Stripe Size: 1024 KB Status: OK MultiDomain Status: OK Caching: Enabled Parity Initialization Status: Initialization Completed Unique Identifier: 600508B1001C7002145360DAB040A14E Disk Name: \\.\PhysicalDrive2 (Disk 2) (Bus: 0,Target: 4,Lun: 0) Mount Points: D:\ 5.5 TB Logical Drive Label: A2D3BB47PAGXQ0ARHZG0UJDCDB Drive Type: Data physicaldrive 1E:1:3 Port: 1E Box: 1 Bay: 3 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 3 TB Firmware Revision: 80.00A80 Serial Number: WD-WCC1T0563051 Model: ATA WDC WD30EFRX-68A SATA NCQ Capable: True SATA NCQ Enabled: True Current Temperature (C): 40 Maximum Temperature (C): 57 PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 1E:1:4 Port: 1E Box: 1 Bay: 4 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 3 TB Firmware Revision: 80.00A80 Serial Number: WD-WCC1T0597161 Model: ATA WDC WD30EFRX-68A SATA NCQ Capable: True SATA NCQ Enabled: True Current Temperature (C): 37 Maximum Temperature (C): 56 PHY Count: 1 PHY Transfer Rate: 1.5Gbps physicaldrive 1E:1:5 Port: 1E Box: 1 Bay: 5 Status: OK Drive Type: Data Drive Interface Type: SATA Size: 3 TB Firmware Revision: 80.00A80 Serial Number: WD-WCC1T0579124 Model: ATA WDC WD30EFRX-68A SATA NCQ Capable: True SATA NCQ Enabled: True Current Temperature (C): 37 Maximum Temperature (C): 52 PHY Count: 1 PHY Transfer Rate: 1.5Gbps Array: B Interface Type: SAS Unused Space: 0 MB Status: OK MultiDomain Status: OK Array Type: Data Logical Drive: 2 Size: 68.3 GB Fault Tolerance: 0 Heads: 255 Sectors Per Track: 32 Cylinders: 17562 Strip Size: 256 KB Full Stripe Size: 256 KB Status: OK MultiDomain Status: OK Caching: Enabled Unique Identifier: 600508B1001C74235292BB43BA16138A Disk Name: \\.\PhysicalDrive3 (Disk 3) (Bus: 0,Target: 5,Lun: 0) Mount Points: None Drive Type: Data physicaldrive 1E:1:1 Port: 1E Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 10000 Firmware Revision: HPD0 Serial Number: B365P7814WTU0735 Model: HP DG072A9BB7 Current Temperature (C): 28 Maximum Temperature (C): 56 PHY Count: 1 PHY Transfer Rate: 3.0Gbps physicaldrive 1E:1:1 Port: 1E Box: 1 Bay: 1 Status: OK Drive Type: Data Drive Interface Type: SAS Size: 72 GB Rotational Speed: 10000 Firmware Revision: HPD0 Serial Number: B365P7814WTU0735 Model: HP DG072A9BB7 Current Temperature (C): 28 Maximum Temperature (C): 56 PHY Count: 1 PHY Transfer Rate: 3.0Gbps Expander 247 Device Number: 247 Firmware Version: A WWID: 500508B300A0D30F Port: 1E Box: 1 Vendor ID: HP Expander 247 Device Number: 247 Firmware Version: A WWID: 500508B300A0D30F Port: 1E Box: 1 Vendor ID: HP Expander 247 Device Number: 247 Firmware Version: A WWID: 500508B300A0D30F Port: 1E Box: 1 Vendor ID: HP SEP (Vendor ID HP, Model P812 INT EXP) 248 Device Number: 248 Firmware Version: 3.10 WWID: 5001438010A1CAE5 Vendor ID: HP Model: P812 INT EXP SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249 Device Number: 249 Firmware Version: RevC WWID: 5001438010A1CAFF Vendor ID: PMCSIERA Model: SRC 8x6G 

在configuration不匹配的情况下,我已经看到了这种情况… P812与MSA50不兼容。 我也看到这种情况下,我有驱动器更换/replace。 无论哪种方式,您将无法查看单个驱动器信息,但是如果磁盘发生故障,警报将指示正确的插槽。

一个例子…下面描述的arrays在托架0-3中是4 x 1TB的驱动器。 但是,据报道,他们在一个海湾。 讨厌,是的…

 [root@Twerk ~]# hpacucli ctrl all show config Smart Array P410i in Slot 0 (Embedded) (sn: 50014380054E9DA0) array A (SAS, Unused Space: 522167 MB) logicaldrive 1 (72.0 GB, RAID 1+0, OK) logicaldrive 2 (1.5 TB, RAID 1+0, OK) physicaldrive 0:0 (box 0:bay 0, SAS, 1 TB, OK) physicaldrive 0:0 (box 0:bay 0, SAS, 1 TB, OK) physicaldrive 0:0 (box 0:bay 0, SAS, 1 TB, OK) physicaldrive 0:0 (box 0:bay 0, SAS, 1 TB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 50014380054E9DAF)