HP 2510G交换机上的环路保护存在问题。
我configuration了Loop-Protect和loop-protect all receiver-action send-disable并设置了transmit-interval 1和disable-timer 30 。
我testing了我的设置:
端口1处的客户端1端口2处的客户端2。
然后,我用端子电缆直接连接端口3和4。
Loop被检测到的次数最多,而Port 3和Port 4则下降了。
从来没有检测到14个环路中的2个,networking将被淹没。
什么可能是错误?
下面是show loop-protect的输出:
ProCurve Switch 2510G-48# show loop-protect Status and Counters - Loop Protection Information Transmit Interval (sec) : 1 Port Disable Timer (sec) : 30 Loop Detected Trap : Disabled Loop Loop Loop Time Rx Port Port Protection Detected Count Since Last Loop Action Status ---- ----------- --------- ---------- ---------------- ------------ -------- 1 Yes No 0 send-disable Down 2 Yes No 0 send-disable Down 3 Yes No 0 send-disable Down 4 Yes No 0 send-disable Down 5 Yes No 0 send-disable Down 6 Yes No 0 send-disable Down 7 Yes No 0 send-disable Down 8 Yes No 0 send-disable Down 9 Yes No 0 send-disable Down 10 Yes No 0 send-disable Down 11 Yes No 0 send-disable Down 12 Yes No 0 send-disable Down 13 Yes No 0 send-disable Down 14 Yes No 0 send-disable Down 15 Yes No 0 send-disable Down 16 Yes No 0 send-disable Down 17 Yes No 0 send-disable Down 18 Yes No 0 send-disable Down 19 Yes No 0 send-disable Down 20 Yes No 0 send-disable Down 21 Yes No 0 send-disable Down 22 Yes No 0 send-disable Down 23 Yes No 0 send-disable Down 24 Yes No 0 send-disable Down 25 Yes No 0 send-disable Down 26 Yes No 0 send-disable Down 27 Yes No 0 send-disable Down 28 Yes No 0 send-disable Down 29 Yes No 0 send-disable Down 30 Yes No 0 send-disable Down 31 Yes No 0 send-disable Down 32 Yes No 0 send-disable Down 33 Yes No 0 send-disable Down 34 Yes No 0 send-disable Down 35 Yes No 0 send-disable Down 36 Yes No 0 send-disable Down 37 Yes No 0 send-disable Down 38 Yes No 0 send-disable Down 39 Yes No 0 send-disable Down 40 Yes No 0 send-disable Down 41 Yes No 0 send-disable Down 42 Yes No 0 send-disable Down 43 Yes No 0 send-disable Down 44 Yes No 0 send-disable Down 45 Yes No 0 send-disable Down 46 Yes No 0 send-disable Down 47 Yes No 0 send-disable Down 48 Yes No 0 send-disable Down ProCurve Switch 2510G-48#
生成树不是一个选项。 networking包含来自不同供应商的交换机,生成树不够兼容。

如果您的交换机至less不支持已经存在近10年的MST ,请更换垃圾 。 禁用生成树是最不正确的解决scheme。
按照richardb的提示,我解决了这个问题。
我如何做到这一点:
所有循环都从现在开始检测。