最近我开始接受(在dmesg)这样的错误:
[ 1569.944985] ata6.01: exception Emask 0x0 SAct 0x0 SErr 0x0 action 0x6 [ 1569.944991] ata6.01: BMDMA stat 0x44 [ 1569.944994] ata6.01: failed command: WRITE DMA [ 1569.944998] ata6.01: cmd ca/00:80:57:7a:6e/00:00:00:00:00/f2 tag 0 dma 65536 out res 51/84:41:96:7a:6e/00:00:00:00:00/f2 Emask 0x10 (ATA bus error) [ 1569.945001] ata6.01: status: { DRDY ERR } [ 1569.945002] ata6.01: error: { ICRC ABRT } [ 1569.945022] ata6: soft resetting link [ 1570.181297] ata6.01: configured for UDMA/100 [ 1570.181314] ata6: EH complete
“smartctl / dev / sda -a”命令说:
SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE (...) 190 Airflow_Temperature_Cel 0x0022 059 045 045 Old_age Always In_the_past 41 (Min/Max 20/41)
但是,当我进行SMART自检时,结果是“完成没有错误”:
SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 6674 - # 2 Extended offline Interrupted (host reset) 60% 6669 - # 3 Short offline Completed without error 00% 6667 -
我的硬盘坏了还是其他地方的问题?
错误是一个总线错误,而不是一个媒体错误,所以是的,问题在别处。 它看起来像一个糟糕的萨塔电缆。