我有一个HP Smart Array P400i RAID控制器 ,有6个磁盘 ,工作在RAID 1 + 0。 这是它的样子:
Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) Mirror Group 1: physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 72 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 72 GB, OK)
如果我的理解是正确的,驱动器1和2可能会失败,并且RAID仍然可以。
这似乎不正确的我,我想在RAID 1 + 0,6驱动器应该是这样的:
Mirror Group 0: physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK) Mirror Group 1: physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 72 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 72 GB, OK) Mirror Group 2: physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 72 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 72 GB, OK)
数据将被分成3个镜像对。
两种configuration都可能,或只是第一个?
您没有select驱动器安排/对。
在这种情况下,HP Smart Array控制器会像这样拆分磁盘:
physicaldrive 1I:1:1 pairs to physicaldrive 1I:1:4 physicaldrive 1I:1:2 pairs to physicaldrive 2I:1:5 physicaldrive 1I:1:3 pairs to physicaldrive 2I:1:6
RAID 1 + 0 == RAID 1对,条带化(RAID 0)…
您可以从上面列出的每个配对丢失一个磁盘。 或者,从每个“镜像组”开一个驱动器。
另外: 什么是不同的广泛使用的RAID级别,我应该什么时候考虑他们?
两种configuration都可能,但使用第一种似乎更危险。
第一种情况是,根据控制器中的实现情况,可能需要更长的重build时间(可能需要读取条带的全部三个驱动器才能重build由三个驱动器组成的镜像),并且如果每个驱动器中有一个丢失条纹设置数组失败。
第二个提供更快的重build(只重build单个驱动器到它的镜像)以及更好的保护每个镜像的驱动器可能会失败,然后arrays不再可用。